高壓二氧化碳滅火系統應用技術(shù)成熟,其設備不僅是性能優(yōu)良的固定滅火設備,也是高壓儲能設備,在努力發(fā)揮正常作用的同時(shí),必須重視施工中對的要求,防止事故的發(fā)生,避免人員和財產(chǎn)的損失。川消高壓二氧化碳滅火系統的要求如下:
The application technology of high-pressure carbon dioxide fire extinguishing system is mature, and its equipment is not only fixed fire extinguishing equipment with excellent performance, but also high-pressure energy storage equipment. While striving to play its normal role, it is necessary to pay attention to the safety requirements during construction, prevent safety accidents from happening, and avoid losses to personnel and property. The safety requirements for the high-pressure carbon dioxide fire extinguishing system of Chuanxiao are as follows:
1、對防護區的要求
1. Requirements for protective zones
(1)防護區內應設有疏散通道和出口,使防護區內的人員能在30s內撤離;
(1) Evacuation routes and safety exits should be set up within the protection zone to enable personnel to evacuate within 30 seconds;
(2)防護區內的疏散通道和出口,應設置應急照明裝置和疏散燈光指示標志,防護區內應設置火災和滅火劑釋放的聲光報警器,并在每個(gè)入口處設置光報警器(放氣指示燈)。
(2) Emergency lighting devices and evacuation light indicator signs should be installed in evacuation routes and safety exits within the protection zone. Sound and light alarms for fire and extinguishing agent release should be installed within the protection zone, and light alarms (vent indicator lights) should be installed at each entrance.
(3)防護區的門(mén)應向外開(kāi)啟,疏散出口的門(mén)必須能從防護區內打開(kāi);
(3) The doors of the protective zone should open outward, and the doors of the evacuation exit must be able to open from within the protective zone;
(4)滅火后防護區應通風(fēng)換氣,當防護區內氧氣濃度低于18%時(shí),人員不允許進(jìn)入防護區。
(4) After extinguishing the fire, the protective area should be ventilated and ventilated. When the oxygen concentration in the protective area is below 18%, personnel are not allowed to enter the protective area.
2、對瓶組間的要求
2. Requirements for bottle groups
(1)瓶組間環(huán)境溫度為:0℃~50℃,并保持干燥和通風(fēng)良好;
(1) The ambient temperature between bottle groups is: 0 ℃~50 ℃, and it should be kept dry and well ventilated;
川消
(2)瓶組間的出口應直接通向室外或疏散通道;
(2) The outlet between bottle groups should directly lead to outdoor or evacuation channels;
(3)瓶組間不允許無(wú)關(guān)人員進(jìn)入;
(3) No unrelated personnel are allowed to enter between bottle groups;
(4)瓶組間門(mén)口設置警告牌。
(4) Set up warning signs at the entrance of the bottle group room.
3、對運輸、搬運和儲存的要求
3. Requirements for transportation, handling, and storage
(1)瓶組屬于壓力容器,應嚴格遵守危險品運輸條例規定;
(1) The bottle group belongs to a pressure vessel and should strictly comply with the regulations on the transportation of dangerous goods;
(2)運輸、搬運過(guò)程中,應輕裝輕卸,防止碰撞、倒置;
(2) During transportation and handling, it should be loaded and unloaded lightly to prevent collision and inversion;
(3)瓶組應避免接近熱源和太陽(yáng)暴曬,以免瓶組受熱內部壓力升高。
(3) The bottle group should avoid being close to heat sources and being exposed to sunlight to avoid internal pressure increase due to heating.
4、對施工、使用和維護的要求
4. Requirements for construction, use, and maintenance
(1)瓶組應固定牢靠,瓶組架必須用地腳螺栓緊固;
(1) The bottle group should be firmly fixed, and the bottle group frame must be fastened with anchor bolts;
(2)電磁型驅動(dòng)裝置上的保險銷(xiāo)在設備未交付使用前不得拆除,以免發(fā)生誤噴事故;
(2) The safety pin on the electromagnetic drive device must not be removed before the equipment is delivered for use to avoid accidental spraying;
(3)各手動(dòng)操作的保險裝置在手動(dòng)操作時(shí)方能拆除,以免發(fā)生誤操作和誤噴事故;
(3) Each manually operated safety device can only be removed during manual operation to avoid accidental operation and spraying accidents;
(4)對于設計中設置備用滅火劑瓶組的滅火設備,平時(shí)主滅火劑瓶組驅動(dòng)氣體管路上的閘閥應保持開(kāi)啟狀態(tài),備用瓶組驅動(dòng)氣體管路上的閘閥應保持關(guān)閉狀態(tài)。
(4) For fire extinguishing equipment with backup fire extinguishing agent bottle groups in the design, the gate valve on the main fire extinguishing agent bottle group driving gas pipeline should be kept open, and the gate valve on the backup bottle group driving gas pipeline should be kept closed.
當滅火設備啟動(dòng)后進(jìn)行恢復時(shí),應先關(guān)閉主滅火劑瓶組的驅動(dòng)氣體管路上的閘閥,擰松該閘閥遠離滅火劑瓶組一端的六角螺母,將驅動(dòng)氣體管路里的剩余驅動(dòng)氣體排盡,再擰緊該六角螺母,打開(kāi)備用滅火劑瓶組驅動(dòng)氣體管路上的閘閥,并使其保持開(kāi)啟狀態(tài)。更多事項就來(lái)我們網(wǎng)站http://www.guizhouhuli.net留言吧!
When the fire extinguishing equipment is restored after startup, the gate valve on the driving gas pipeline of the main fire extinguishing agent bottle group should be closed first, and the hexagonal nut at the end far from the fire extinguishing agent bottle group should be loosened to exhaust the remaining driving gas in the driving gas pipeline. Then, the hexagonal nut should be tightened to open the gate valve on the driving gas pipeline of the backup fire extinguishing agent bottle group and keep it open. For more information, come to our website http://www.guizhouhuli.net Leave a message!